• Home
  • ANTISCALANTS
  • FILMTEC MEMBRANES
    • Convertor
    • Filmtec Parts
    • CARWASH SPOT FREE COMPS
    • MAPLE SAP MEMBRANE
  • FILTERS- MATRIKX (KX)
    • MARTIKX Pricing
  • FILTERS - PENTAIR
  • FILTERS-G.E.PURTREX
  • HOUSINGS-CODELINE
  • CODELINE ADAPTER
  • HOUSINGS- S.S. & PVF
  • HOUSING-SW COMCON
  • HOUSING - SW HCTI
  • PUMPS-PROCON
  • R.O. SYSTEMS
  • TRADE SHOWS
  • UF HOLLOW FIBER - DOW
  • Contact/Place Order
Filmtec Membranes Dow Filmtec KX Matrikx Filters pentek filters Procon Pumps Purtrex Filters Codeline housings pressure vessels membrane housings maple sap membranes dow filmtec TRISEP MEMBRANES

AMERICAN RO

Call 859-624-8577 / U.S. Toll Free (866) 484-2767 | /americanro@aol.com
DOW Ultrafiltration
**** CALL / EMAIL FOR PRICING - ITEMS NOW STOCKED THE THE US****

SFP-2660 and SFD-2660 Modules

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m3/hr (220 gpm) or less. The shorter, 60 inch length module offers higher efficiencies over a wider range of feed water conditions compared to longer length modules. The smaller, 6 inch diameter module allows a more compact design for space constrained installations.

Product Specifications

MODEL
TYPE
MEMBRANE AREA ft2 (m2)
MODULE VOLUME gallons (liters)
WEIGHT - EMPTY lbs (kg)
WEIGHT - FILLED lbs (kg)
SFP-2660
Pretreatment
355 (33)
4.2 (16)
55 (25)
90 (41)
SFD-2660
NSF/ANSI 61 Drinking Water
355 (33)
4.2 (16)
55 (25)
90 (41)

SFP-2860 and SFD-2860 Modules

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m³/hr (220 gpm) or less. The larger, 8 inch diameter module offers the highest effective membrane area of the DOW UF modules, which contributes to a more economical membrane system design. The shorter, 60 inch length module offers higher efficiencies over a wider range of feed water conditions compared to longer length modules.

Product Specifications

MODEL
TYPE
MEMBRANE AREA ft² (m²)
MODULE VOLUME gallons (liters)
WEIGHT - EMPTY lbs (kg)
WEIGHT - FILLED lbs (kg)
SFP-2860
Pretreatment
549 (51)
9.3 (35)
106 (48)
183 (83)
SFD-2860
NSF/ANSI 61 Drinking Water
549 (51)
9.3 (35)
106 (48)
183 (83)

SFP-2880 and SFD-2880 Modules

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m3/hr (220 gpm) or more. Larger and longer, 8 inch diameter and 80 inch in length, together with an increase in packing density of 10,000 fibers, this module offers the highest effective membrane area of the DOW Ultrafiltration modules. The 2880 contributes to a more economical membrane system design.

Product Specifications

MODEL
TYPE
MEMBRANE AREA ft2 (m2)
MODULE VOLUME gallons (liters)
WEIGHT - EMPTY lbs (kg)
WEIGHT - FILLED lbs (kg)
SFP-2880
Pretreatment
829 (77)
10.3 (39)
135 (61)
220 (100)
SFD-2880
NSF/ANSI 61 Drinking Water
829 (77)
10.3 (39)
135 (61)
220 (100)

What is UF?

Ultrafiltration or UF is a pressure driven membrane separation process that separates particulate matter from soluble components in the carrier fluid (such as water). UF membranes typically have pore sizes in the range of 0.01 - 0.10 µm and have a high removal capability for bacteria and most viruses, colloids and silt (SDI). The smaller the nominal pore size, the higher the removal capability. Most materials that are used in UF are polymeric and are naturally hydrophobic. Common polymeric materials used in UF include: Polysulfone (PS), Polyethersulfone (PES), Polypropylene (PP), or Polyvinylidenefluoride (PVDF). Although these materials can be blended with hydrophilic agents, they can reduce the membranes ability to be cleaned with high strength disinfectants such as hypochlorite that impacts removal of bacterial growth.
The DOW™ Ultrafiltration module utilizes a double-walled hollow fiber (capillary) PVDF membrane which has a very small nominal pore diameter for PVDF material that allows for the removal of all particulate matter, bacteria and most viruses and colloids. Despite the small pore diameter, the membrane has a very high porosity resulting in a flux similar to that of micro-filtration (MF) and can effectively replace MF in most cases.
Systems designed with DOW Ultrafiltration use an outside-in flow configuration which allows for less plugging, higher solids loading, higher flow area and easy cleaning. The primary flow design is dead-end filtration but the module can be operated using a concentrate bleed. Dead-end filtration uses less energy and has a lower operating pressure than the concentrate bleed, therefore reducing operating costs.
Typically, DOW Ultrafiltration is operated at a constant permeate flow. The transmembrane pressure (TMP) will naturally increase over time and the module can be cleaned periodically by back flushing and air scouring to remove the fouling layer. Disinfectants and other cleaning agents can be used to fully remove and prevent performance loss due to biological growth as well as other foulants.

DOW™ Ultrafiltration Technology

The DOW™ Ultrafiltration double-walled hollow fiber membrane is formed from high grade polymeric chemicals. The virtually defect-free, double-walled fiber membrane is much more robust and less prone to breakage than single-wall hollow fibers but due to the high pore distribution, does not compromise flux. The uniformity of pore size and outside-in flow ensures the DOW™ Ultrafiltration membrane creates a perfect barrier without sacrificing performance.

DOW™ Ultrafiltration Advantages

  • Low fouling Hydrophilic Polyvinylidenefluoride (H-PVDF) membrane
  • Excellent filtration performance with high flux
  • Durable and break resistant double- walled fiber structure
  • High chemical resistance and temperature tolerance for effective membrane cleaning
  • Very fine nominal pore diameter (0.03 µm)
  • High removal efficiency of bacteria and viruses
  • Dead-end or concentrate bleed flow capabilities
  • Outside-In flow configuration that allows for less plugging and higher solids loading, higher flow area and easier cleaning
  • Can be periodically back washed and air scoured to improve performance and extend operating life by removing the fouling layer
  • Simple, vertical, modular design allows low cost, compact systems
THIS PRODUCT IS FOR NEW EQUIPMENT AND TARGETED TOWARDS OEMS ONLY. CALL OR EMAIL FOR PRICING AND ASSISTANCE WITH COMPUTER DESIGN PROPOSAL FROM DOW.
Home | ANTISCALANTS | FILMTEC MEMBRANES | FILTERS- MATRIKX (KX) | FILTERS - PENTAIR | FILTERS-G.E.PURTREX | HOUSINGS-CODELINE | CODELINE ADAPTER | HOUSINGS- S.S. & PVF | HOUSING-SW COMCON | HOUSING - SW HCTI | PUMPS-PROCON | R.O. SYSTEMS | TRADE SHOWS | UF HOLLOW FIBER - DOW | Contact/Place Order
AMERICAN R.O. SYSTEMSRICHMOND, KY 40475-8209
Phone: 8596248577Fax: (859)624-8577Toll Free: (866)484-2767AMERICANRO@AOL.COM
Copyright © 2026 Web Design by Web.com Group, Inc.

We use cookies to enable essential functionality on our website and analyze website traffic. For more information, read our Cookies and Privacy Policy.

Your Cookie Settings

We use cookies to enable essential functionality on our website and analyze website traffic. For more information, read our Cookies and Privacy Policy below..

Cookie Categories
Essential

These cookies are strictly necessary to provide you with services available through our websites.

Analytics

These cookies collect information that is used in aggregate and in an anonymized form to help us understand how our website is being used and how effectively our site is performing.