Filmtec Membranes Dow Filmtec KX Matrikx Filters pentek filters Procon Pumps Purtrex Filters Codeline housings pressure vessels membrane housings maple sap membranes dow filmtec TRISEP MEMBRANES

AMERICAN RO

Call 859-624-8577 / U.S. Toll Free (866) 484-2767 | /americanro@aol.com
Home
ANTISCALANTS
FILMTEC  MEMBRANES
FILTERS- MATRIKX (KX)
FILTERS - PENTAIR
FILTERS-G.E.PURTREX
HOUSINGS-CODELINE
CODELINE ADAPTER
HOUSINGS- S.S. & PVF
HOUSING-SW COMCON
HOUSING - SW HCTI
PUMPS-PROCON
R.O. SYSTEMS
UF HOLLOW FIBER -  DOW
Contact/Place Order

DOW Ultrafiltration

 **** CALL / EMAIL FOR PRICING - ITEMS NOW STOCKED THE THE US****

SFP-2660 and SFD-2660 Modules

 

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m3/hr (220 gpm) or less. The shorter, 60 inch length module offers higher efficiencies over a wider range of feed water conditions compared to longer length modules. The smaller, 6 inch diameter module allows a more compact design for space constrained installations.

Product Specifications

 

MODEL TYPE MEMBRANE AREA
ft2 (m2)
MODULE VOLUME
gallons (liters)
WEIGHT - EMPTY
lbs (kg)
WEIGHT - FILLED
lbs (kg)
SFP-2660 Pretreatment 355 (33) 4.2 (16) 55 (25) 90 (41)
SFD-2660 NSF/ANSI 61
Drinking Water
355 (33) 4.2 (16) 55 (25) 90 (41)

 

SFP-2860 and SFD-2860 Modules

 

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m3/hr (220 gpm) or less. The larger, 8 inch diameter module offers the highest effective membrane area of the DOW UF modules, which contributes to a more economical membrane system design. The shorter, 60 inch length module offers higher efficiencies over a wider range of feed water conditions compared to longer length modules.

 

Product Specifications

 

MODEL TYPE MEMBRANE AREA
ft2 (m2)
MODULE VOLUME
gallons (liters)
WEIGHT - EMPTY
lbs (kg)
WEIGHT - FILLED
lbs (kg)
SFP-2860 Pretreatment 549 (51) 9.3 (35) 106 (48) 183 (83)
SFD-2860 NSF/ANSI 61
Drinking Water
549 (51) 9.3 (35) 106 (48) 183 (83)

 

SFP-2880 and SFD-2880 Modules

 

These DOW™ Ultrafiltration modules are an ideal choice for system capacities of 50 m3/hr (220 gpm) or more. Larger and longer, 8 inch diameter and 80 inch in length, together with an increase in packing density of 10,000 fibers, this module offers the highest effective membrane area of the DOW Ultrafiltration modules. The 2880 contributes to a more economical membrane system design.

 

Product Specifications

 

MODEL TYPE MEMBRANE AREA
ft2 (m2)
MODULE VOLUME
gallons (liters)
WEIGHT - EMPTY
lbs (kg)
WEIGHT - FILLED
lbs (kg)
SFP-2880 Pretreatment 829 (77) 10.3 (39) 135 (61) 220 (100)
SFD-2880 NSF/ANSI 61
Drinking Water
829 (77) 10.3 (39) 135 (61) 220 (100)

 

What is UF?

 

DOW Ultrafiltration ModuleUltrafiltration or UF is a pressure driven membrane separation process that separates particulate matter from soluble components in the carrier fluid (such as water). UF membranes typically have pore sizes in the range of 0.01 - 0.10 µm and have a high removal capability for bacteria and most viruses, colloids and silt (SDI). The smaller the nominal pore size, the higher the removal capability. Most materials that are used in UF are polymeric and are naturally hydrophobic. Common polymeric materials used in UF include: Polysulfone (PS), Polyethersulfone (PES), Polypropylene (PP), or Polyvinylidenefluoride (PVDF). Although these materials can be blended with hydrophilic agents, they can reduce the membranes ability to be cleaned with high strength disinfectants such as hypochlorite that impacts removal of bacterial growth.

The DOW™ Ultrafiltration module utilizes a double-walled hollow fiber (capillary) PVDF membrane which has a very small nominal pore diameter for PVDF material that allows for the removal of all particulate matter, bacteria and most viruses and colloids. Despite the small pore diameter, the membrane has a very high porosity resulting in a flux similar to that of micro-filtration (MF) and can effectively replace MF in most cases.

Systems designed with DOW Ultrafiltration use an outside-in flow configuration which allows for less plugging, higher solids loading, higher flow area and easy cleaning. The primary flow design is dead-end filtration but the module can be operated using a concentrate bleed. Dead-end filtration uses less energy and has a lower operating pressure than the concentrate bleed, therefore reducing operating costs.

Typically, DOW Ultrafiltration is operated at a constant permeate flow. The transmembrane pressure (TMP) will naturally increase over time and the module can be cleaned periodically by back flushing and air scouring to remove the fouling layer. Disinfectants and other cleaning agents can be used to fully remove and prevent performance loss due to biological growth as well as other foulants.

 

DOW™ Ultrafiltration Technology

 

An electronmicrograph image of a cross-section of a DOW UF double-walled

The DOW™ Ultrafiltration double-walled hollow fiber membrane is formed from high grade polymeric chemicals. The virtually defect-free, double-walled fiber membrane is much more robust and less prone to breakage than single-wall hollow fibers but due to the high pore distribution, does not compromise flux. The uniformity of pore size and outside-in flow ensures the DOW™ Ultrafiltration membrane creates a perfect barrier without sacrificing performance.

 

               DOW™ Ultrafiltration Advantages

  • Low fouling Hydrophilic Polyvinylidenefluoride (H-PVDF) membrane
  • Excellent filtration performance with high flux
  • Durable and break resistant double- walled fiber structure
  • High chemical resistance and temperature tolerance for effective membrane cleaning
  • Very fine nominal pore diameter (0.03 µm)
  • High removal efficiency of bacteria and viruses
  • Dead-end or concentrate bleed flow capabilities
  • Outside-In flow configuration that allows for less plugging and higher solids loading, higher flow area and easier cleaning
  • Can be periodically back washed and air scoured to improve performance and extend operating life by removing the fouling layer
  • Simple, vertical, modular design allows low cost, compact systems 

 

THIS PRODUCT IS FOR NEW EQUIPMENT AND TARGETED TOWARDS OEMS ONLY. CALL OR EMAIL FOR PRICING AND ASSISTANCE WITH COMPUTER DESIGN PROPOSAL FROM DOW.